There’s nothing ordinary about Trumbull standard built-up roofing asphalts. Like every asphalt we make, our standard Types I - IV asphalts meet or exceed ASTM standards in every category.

We exceed ASTM minimum softening points to minimize the risk of slippage and reduce "fallback." We use high flashpoint raw materials to provide added safety. We also widen the spread between equiviscous temperature (EVT) and flashpoint to support application, adhesion and waterproofing.

And to make sure our products are consistently reaching those standards, we test not once, but twice. First they’re tested at our on-site plant laboratories then again at our Summit, Illinois, Technological Laboratory – one of a select few certified by the AASHTO (American Association of State Highway Testing Officials.)

Enhancing the capabilities of asphalt to better address your needs. We call it Applied Innovation™. You know it as Trumbull quality. The highest standard in the built-up roofing asphalt industry.

Standard Type I - IV Asphalts MSDS Sheet

Features Benefits
All products meet ASTM D312 Each shipment meets or exceeds the physical requirements of the specified roofing grade asphalt

Consistent high flash material Proper temperature range needed to apply product safely at the EVT; flash points typically 50ºF to 75ºF higher than the 500ºF minimum

Testing in each plant and at Summit, IL laboratory All Owens Corning Trumbull products are assured to meet ASTM requirements

19 producing plants Convenient, accessible availability from coast to coast

EVT shown on each carton and bill of lading for bulk shipments Assures proper adhesion, waterproofing and application rate

Printed cartons Clearly identifies manufacturers, type, flash point, EVT, production location and production date


Physical Requirements - ASTM D312-00
    Type I Type II Type III Type IV Test Methods
    Min. Max. Min. Max. Min. Max. Min. Max.
Softening Point (ºF) 135 151 158 176 185 205 210 225 ASTM D36

Flash Point (ºF) 500 500 500 500 ASTM D92

Penetration, Units, dmm:
@32ºF 3 6 6 6 ASTM D5
@77ºF 18 60 18 40 15 35 12 25  
@115ºF 90 180 100 90 75  

Ductility @77ºF, cm 10.0 3.0 2.5 1.5 ASTM D113

Solubility in Trichoroethylene % 99 99 99 99 ASTM D2042

Asphalts shall be homogenous and free of water and shall conform to these physical properties


Typical Physical Characteristics for Trumbull Asphalt
    Type I Type II Type III Type IV   
Softening Point (ºF) 140-145 165-175 195-205 210-225

Flash Point (ºF) 525 525 525 525

Penetration, Units, dmm:
@32ºF 6 8 6 6
@77ºF 20-35 18-30 16-24 13-22

Ductility @77ºF, cm 13 4.0 3.0 2.0

Solubility in Trichoroethylene % 99.8 99.8 99.8 99.8

Typical Application Temperature
For Hand Mopping
EVT @125 CPS +/- 25ºF 350 375 410 440
For Machine Spreader
EVT @ 75 CPS +/- 25ºF 370 395 430 460

Plant Specific EVTs